FuelControl UK All articles
Telematics & Fleet Operations

Keeping Thirty Vans Moving When the Forecourt Fails

FuelControl UK
Keeping Thirty Vans Moving When the Forecourt Fails

Photo: U.S. Navy photo by Mass Communication Specialist 2nd Class Zachary D. Behrend, Public domain, via Wikimedia Commons

Most fuel plans assume that the card works, the forecourt has stock and the supplier delivers on time. The day one of those assumptions fails, a thirty-van operation can lose a morning to queuing, panic-buying and contradictory instructions. Fuel continuity is therefore not a crisis response. It is a small set of decisions made before the pumps go dark.

Name the failure you are planning for

Continuity planning starts with specificity. A fuel-card network outage is different from a local shortage, and both are different from a depot supplier that cannot deliver. The first is a payment problem: the fuel is there but the card is not accepted. The second is a stock problem: cards may work but forecourts are dry. The third is a delivery problem: the depot tank is low and the scheduled load has not arrived.

Each failure needs a different first move. For a card outage, the answer is a backup payment method and a list of stations that accept it. For a local shortage, the answer is priority allocation and a wider radius. For a supplier failure, the answer is a secondary account and a measured reserve. A single plan that treats all three as one emergency will be too vague to use on the morning.

Set priority refuelling rules

In a constrained fuel environment, not every journey has equal claim on the tank. Divide the fleet into three tiers. Critical vehicles are those whose failure would stop a contractual service, a statutory duty or a safety response. Core vehicles are those that keep normal revenue work moving. Discretionary vehicles are those whose work can be deferred by a day or two without penalty.

Publish the tiers before the event and apply them without negotiation. Critical vehicles refuel first and may use the reserve. Core vehicles refuel to a working level, not necessarily a full tank. Discretionary vehicles stand down or take only what is needed to return to base. A simple daily allocation, such as a maximum litre amount per vehicle, prevents one driver from filling every available container while another is left short.

Avoid the instruction to fill every tank at the first sign of trouble. Topping up thirty vans from half-full adds hundreds of litres of unnecessary demand and creates the very queue the plan is meant to avoid. A 50% trigger for critical vehicles and a 25% trigger for core vehicles is easier to manage than a blanket full-tank rule.

Hold a reserve without tying up cash

A reserve is not a stockpile. For most light commercial fleets, one to two days of normal consumption is enough to bridge a card outage or a missed delivery. Thirty vans using roughly 60 litres a day each would need 1,800 litres for one day; two days would be 3,600 litres. At around £1.45 per litre, that is a meaningful but not enormous cash commitment. The bigger issues are storage compliance, fire safety, bunding and fuel quality.

Where an on-site tank already exists, keep it rotated and treated as operational stock rather than a museum exhibit. Where it does not, do not buy an unauthorised container farm. Instead, set up a secondary fuel-card account with a different network, identify two or three local independents that accept it, and keep a modest cash float or prepaid card for genuine exceptions. The aim is optionality, not hoarding.

Communicate once, clearly and repeatedly

Drivers in a fuel event are exposed to rumour, radio phone-ins and social media. The fleet office should issue one instruction through one channel, with a named contact and a review time. A short message works better than a long policy document: which vehicles may fuel, where they may fuel, how much they may take, what to do if the card is declined, and when the next update will arrive.

Drivers should also be told what not to do: do not fill portable containers, do not queue across a forecourt entrance, do not use a higher-grade fuel as a substitute, and do not pay cash without a receipt and an authorisation reference. Forecourt staff are more likely to help a fleet that behaves calmly than one that blocks the pumps.

Keep the paperwork moving

A continuity event is exactly when fuel records become messy. Manual fuel logs should capture vehicle registration, driver, date, time, litres, price, station and payment method. Receipts should be retained even when the card is not used. Exception reports should be completed within 48 hours, not at month-end, so that the fleet office can reconcile the event while memories are fresh.

For VAT and audit purposes, a missing receipt is not a trivial matter. A signed driver declaration may support the claim, but it does not replace a proper invoice where one is available. The fleet manager should also record why a vehicle was authorised to refuel outside the normal policy, because the exception will be questioned later.

Review while the event is still fresh

Within a week of normal service returning, hold a short review. Which stations failed first? How long did the reserve last? Did the priority tiers hold? Which drivers ran out of fuel, and why? The answers should update the contact list, the station list and the reserve calculation. Continuity planning is not a document to be filed. It is a routine that improves each time it is tested, whether by a real shortage or by a controlled exercise.

All Articles

Related Articles

Warm Cabs, Cold Cash: The Real Cost of Yard Idling in UK Depots

Warm Cabs, Cold Cash: The Real Cost of Yard Idling in UK Depots

Soot in the Sump: The Fuel a Short-Hop Van Burns Cleaning Its Own Filter

Soot in the Sump: The Fuel a Short-Hop Van Burns Cleaning Its Own Filter

The Blue Tank Audit: Keeping AdBlue Quality and Purchasing Under Control

The Blue Tank Audit: Keeping AdBlue Quality and Purchasing Under Control